| MODEL | Unit | SQ-3350 | ||
|---|---|---|---|---|
| Type | - | Revolving field, brushless AC generator | ||
| Frequency | Hz | 60 | ||
| Standby Output | kVA (kW) | 38.5 (30.8) | ||
| Prime Output | kVA (kW) | 35.0 (28.0) | ||
| Voltage - Single Phase | V | 127 | 220 | |
| Voltage - Three Phase | V | 220 | 380 | |
| Armature Connection | - | Star with neutral | ||
| Phase / Wire | - | 3/12 | ||
| Power Factor | - | 0.8 | ||
| No. of Poles | - | 4 | ||
| Insulation | Class | H | ||
| Voltage Regulation | % | 1.5 (No load to full load) | ||
| Type of Coupling | - | Direct coupled | ||
| AMPS | ||||
| Three Phase 220V | A | 91.9 | - | |
| Three Phase 380V | A | - | 53.2 | |
| TERMINAL | ||||
| Terminal | - | Available | ||
| DIESEL ENGINE | ||||
| Type | - | Vertical, water-cooled, 4-cycle diesel engine | ||
| Model | - | V3300 | ||
| No. of Cylinders | - | 4 | ||
| Bore x Stroke | mm (in.) | 98.0 x 110.0 (3.86 x 4.33) | ||
| Displacement | L (cu. in.) | 3.318 (202.5) | ||
| Engine Speed | rpm | 1800 | ||
| Continuous Rated Output | kW (HP) | 32.1 (43.0) | ||
| Lubricant (API classification) | - | above CD grade | ||
| Oil Capacity | L (qts.) | 13.2 (14.0) | ||
| Coolant Capacity | L (qts.) | 8.2 (8.7) | ||
| Starting System | - | Electric - 12 volt DC | ||
| SET | ||||
| Fuel | - | Diesel fuel No.2 (ASTM D975) | ||
| Fuel Consumption | at Full Load | L/h (gal./h) | 9.1 (2.4) | |
| at 3/4 Load | L/h (gal./h) | 7.0 (1.8) | ||
| at 1/2 Load | L/h (gal./h) | 5.2 (1.4) | ||
| at 1/4 Load | L/h (gal./h) | 3.8 (1.0) | ||
| Fuel Tank Capacity | L (gal.) | 68.0 (18.0) | ||
| Continuous Operation Hours | at Full Load | h | 7.5 | |
| at 3/4 Load | h | 9.7 | ||
| at 1/2 Load | h | 13.1 | ||
| at 1/4 Load | h | 17.9 | ||
| Battery (Ah/5 h) | - | 12 V (92 Ah) | ||
| Dimensions L x W x H | mm (in.) | 1935 x 860 x 995 (76.2 x 33.9 x 39.2) | ||
| Approx. Net Weight | kg (lbs.) | 880 (1940) | ||
| Sound Level (Full Load at 23 ft. [7m]) | dB (A) | 65 | ||
| Emergency Stop System | - | In case of abnormal: Oil pressure, water temperature, fan belt broken When the side cover and door open with running | ||